Generator & Backup Power Calculator

What size generator do you need? Add your appliances and equipment — we account for motor starting currents and safe continuous loading, then recommend the generator kVA, inverter size and battery bank. Free, instant, engineer-built.

1 · Add your equipment

2 · Your load list

LED lights (×10)
100 W each
1
100 W
Fridge / freezer
300 W each · motor start ×3
1
300 W
TV & decoder
150 W each
1
150 W

3 · Battery backup preferences

Your sizing result
Running load
550 W
Peak (with motor start)
1,150 W
Recommended generator
2.5 kVA

Sized at 0.8 power factor with the continuous load held below 75% of rating — the way a generator should be run for engine life.

Inverter alternative
Inverter size
1 kW
Battery bank (4 h @ 48 V)
70 Ah

Lithium assumed (80% usable capacity, 90% inverter efficiency). Heavy heating loads (geyser, stove, kettle) are usually moved off inverter circuits — we design that split at assessment.